What Is Oven Temperature Calibration
Oven temperature calibration is the process of verifying and documenting the temperature accuracy, uniformity, and control system performance of industrial ovens used in manufacturing, heat treating, and processing operations. Calibration is performed to ensure that the actual temperature within the oven workspace matches the setpoint temperature within specified tolerances, and that temperature distribution across the qualified work zone meets the requirements of applicable industry standards.
Two primary types of oven calibration are performed: Temperature Uniformity Surveys (TUS), which measure the spatial temperature distribution throughout the oven work zone, and System Accuracy Tests (SAT), which verify the accuracy of the oven's temperature control and recording instrumentation. Both are required under AMS 2750H and related pyrometry specifications for ovens used in aerospace, automotive, and other regulated heat treating applications.
Industrial ovens subject to calibration include batch ovens, continuous conveyor ovens, walk-in ovens, drying ovens, curing ovens, aging ovens, and any thermal processing equipment where product quality is dependent on temperature accuracy and uniformity. Calibration is performed on-site at the facility where the oven is installed and operated.
The Oven Calibration Process
Step 1: Pre-Survey Assessment
Prior to performing any temperature measurements, a complete assessment of the oven is conducted. The oven's physical condition, door seals, heating elements, air circulation system, and insulation are inspected. The existing temperature control instrumentation — including controllers, recorders, and over-temperature safety devices — is identified and its calibration status is reviewed. The qualified work zone dimensions are confirmed, and the number and placement of survey thermocouples are determined based on the oven volume and the requirements of the applicable specification.
Step 2: System Accuracy Test (SAT)
A System Accuracy Test is performed to verify the accuracy of the oven's temperature sensing, control, and recording instruments. An SAT compares the readings of the oven's installed sensors against NIST-traceable reference thermocouples placed at the same location within the oven. The difference between the oven's displayed temperature and the reference thermocouple reading is recorded and evaluated against the allowable tolerances specified in AMS 2750H. SATs are required to be performed at regular intervals — typically monthly or quarterly — depending on the oven classification and the applicable pyrometry specification.
Step 3: Temperature Uniformity Survey (TUS)
A Temperature Uniformity Survey measures the temperature distribution throughout the oven's qualified work zone. NIST-traceable survey thermocouples are placed at specified locations within the work zone — typically at the corners and center of the usable volume. The oven is brought to each qualified operating temperature, and thermocouple readings are recorded at defined intervals once the oven has stabilized. The range of temperature readings across all survey thermocouples at each setpoint is compared against the uniformity tolerance specified for the oven's classification under AMS 2750H.
The number of survey thermocouples required depends on the volume of the qualified work zone. AMS 2750H specifies minimum thermocouple counts ranging from 9 sensors for small ovens to 40 or more sensors for large walk-in ovens. Survey thermocouples must be distributed to adequately characterize the temperature profile of the entire work zone.
Step 4: Overshoot and Recovery Testing
When required by the applicable specification or customer requirements, overshoot and recovery testing is performed. Overshoot testing measures the maximum temperature excursion above the setpoint during initial heat-up, and recovery testing measures the time required for the oven to return to within the specified uniformity tolerance after a load is introduced or a door is opened. These tests are documented and evaluated against the allowable limits.
Step 5: Documentation and Certification
Upon completion of all calibration measurements, a comprehensive calibration report and certificate are issued. The report includes all thermocouple placement locations, as-found and as-left temperature readings at each survey point, calculated temperature uniformity at each setpoint, SAT results with deviations from reference standards, identification of all NIST-traceable reference equipment used, and a statement of measurement uncertainty. All certificates are issued under the scope of an ISO/IEC 17025 accredited laboratory.
Compliance & Standards
AMS 2750H — Pyrometry
AMS 2750H is the primary pyrometry specification governing the calibration, testing, and documentation requirements for thermal processing equipment used in aerospace and other regulated industries. Published by SAE International, AMS 2750H defines the requirements for temperature uniformity surveys, system accuracy tests, thermocouple types, instrumentation accuracy classes, and the frequency of required testing. Compliance with AMS 2750H is mandatory for heat treating facilities serving the aerospace industry and is required by most Nadcap-accredited operations.
Nadcap — Aerospace Quality
The National Aerospace and Defense Contractors Accreditation Program (Nadcap) is a cooperative accreditation program administered by the Performance Review Institute (PRI). Nadcap accreditation for heat treating requires demonstrated compliance with AMS 2750H pyrometry requirements, including regular temperature uniformity surveys and system accuracy tests performed by qualified personnel using NIST-traceable reference standards. Nadcap audits evaluate both the heat treating processes and the supporting pyrometry and calibration documentation.
AIAG CQI-9 — Automotive Heat Treating
The Automotive Industry Action Group (AIAG) CQI-9 Special Process: Heat Treat System Assessment is the automotive industry's standard for evaluating heat treating operations. CQI-9 includes specific requirements for oven and furnace calibration, temperature uniformity testing, and pyrometry documentation. Automotive OEMs and Tier 1 suppliers typically require CQI-9 compliance from their heat treating providers, and the pyrometry requirements within CQI-9 align with AMS 2750H.
Additional Standards
- ISO/IEC 17025 — General requirements for the competence of testing and calibration laboratories
- ASTM E220 — Standard Test Method for Calibration of Thermocouples
- AMS 2769 — Heat Treatment of Parts, General Requirements
- BAC 5621 — Boeing Process Specification for Heat Treating
- MIL-STD-1684 — Department of Defense Standard Practice for Pyrometry
Industry Applications
Aerospace & Defense
Oven temperature calibration is performed at aerospace manufacturing and MRO facilities where heat treating of turbine components, structural alloys, and fasteners is conducted. Compliance with AMS 2750H and Nadcap pyrometry requirements is mandatory. Temperature uniformity surveys and system accuracy tests are performed at intervals specified by the applicable customer specifications and prime contractor flow-downs.
Automotive Manufacturing
Automotive heat treating operations — including carburizing, hardening, tempering, and stress relieving — require calibrated ovens with documented temperature uniformity. AIAG CQI-9 assessments require current TUS and SAT records for all thermal processing equipment. Oven calibration is performed at automotive OEM plants, Tier 1 and Tier 2 supplier facilities, and independent commercial heat treaters.
Metal Processing & Heat Treating
Commercial heat treating facilities, metal finishing operations, powder metallurgy plants, and additive manufacturing operations rely on calibrated ovens for process consistency. Temperature uniformity directly impacts metallurgical properties including hardness, tensile strength, grain structure, and case depth. Regular oven calibration ensures that thermal processes remain within specification.
Composites & Advanced Materials
Curing ovens used in composite manufacturing — including autoclave alternatives for vacuum bag processing — require calibrated temperature profiles to achieve proper resin cure. Temperature uniformity across the part surface is critical for structural integrity. Calibration of curing ovens is performed to the uniformity tolerances specified by the composite material manufacturer and the applicable process specification.
Oven Temperature Calibration in Racine
On-site oven temperature calibration is performed at manufacturing, heat treating, and processing facilities in Racine and the surrounding Wisconsin area. Temperature uniformity surveys and system accuracy tests are conducted by ISO/IEC 17025 accredited laboratories using NIST-traceable reference thermocouples and data acquisition equipment. All calibration certificates are issued on-site upon completion of the measurement work.
Facilities in Racine, WI requiring oven calibration for AMS 2750H, Nadcap, CQI-9, or customer-specific pyrometry requirements are served through Temperature Calibration Specialists. Standard and priority scheduling is available.
Accredited
Compliant
Traceable
Ready
Schedule Oven Calibration in Racine
ISO/IEC 17025 accredited oven temperature calibration — including temperature uniformity surveys and system accuracy tests — is available on-site at facilities in Racine. Contact us to schedule service or request a quote.