Environmental Chamber Calibration in Rockford

ISO/IEC 17025 accredited environmental chamber calibration, stability chamber mapping, thermal cycling verification, and humidity mapping in Rockford, IL.
Standards: IEC 60068, ISTA protocols
Schedule Calibration Call: (630) 488-6751

What Is Environmental Chamber Calibration

Environmental chamber calibration is the process of verifying and documenting the temperature accuracy, uniformity, and stability of environmental test chambers, stability chambers, and climate-controlled enclosures. Calibration includes temperature mapping of the chamber workspace to identify spatial temperature variations and verify that all locations within the usable volume meet specified uniformity tolerances.

Environmental chambers subject to calibration include stability chambers (used for pharmaceutical shelf-life testing under ICH conditions), thermal cycling chambers (for accelerated aging and reliability testing), temperature/humidity chambers (for combined environmental stress testing), walk-in environmental rooms, HALT/HASS chambers (Highly Accelerated Life Testing / Highly Accelerated Stress Screening), thermal shock chambers, and altitude simulation chambers.

When chambers control both temperature and humidity, calibration includes verification of both parameters. Humidity mapping determines the distribution and accuracy of relative humidity across the chamber workspace. Temperature and humidity are mapped simultaneously to characterize the interaction between the two controlled parameters under steady-state and transitional conditions.

The Environmental Chamber Calibration Process

Step 1: Chamber Assessment and Planning

Physical inspection of the chamber is conducted, including door seals, heating and cooling elements, air circulation system, humidification system (if applicable), and control instrumentation. Chamber specifications are reviewed, including temperature range, humidity range (if applicable), uniformity specification, and stability specification. Sensor placement grid is determined based on chamber volume and applicable standard requirements. Product loading configuration is reviewed for loaded-condition mapping.

Step 2: Temperature Mapping — Empty Chamber

NIST-traceable temperature sensors are placed at defined grid positions throughout the chamber workspace — typically at corners and center of the usable volume on multiple levels. The chamber is operated at each qualified temperature setpoint, and temperature data is recorded continuously once steady-state conditions are achieved. Spatial temperature uniformity (variation between sensors at a given time) and temporal stability (variation of a single sensor over time) are calculated at each setpoint. Hot spots and cold spots are identified and documented.

Step 3: Humidity Mapping (If Applicable)

For chambers controlling relative humidity, calibrated humidity sensors are placed at defined locations within the workspace. Humidity mapping is performed simultaneously with temperature mapping. The accuracy and uniformity of relative humidity across the workspace are verified at each qualified condition (temperature/humidity combination). Humidity sensor calibration is NIST-traceable to national standards through calibrated salt solutions or chilled mirror hygrometers.

Step 4: Door Open Recovery and Loaded-Condition Testing

Door open recovery testing measures the time required for the chamber to return to within specified tolerances after the door is opened and closed, simulating normal operational conditions. When required, loaded-condition mapping is performed with actual or simulated product loads to characterize the impact of thermal mass on temperature distribution and recovery time. Loaded-condition results are compared against empty-chamber baseline data.

Step 5: Documentation and Certification

Calibration report and certificate are issued under ISO/IEC 17025 accredited laboratory scope. Documentation includes sensor placement diagram, temperature (and humidity) data at each mapping point, calculated uniformity and stability values at each setpoint, hot/cold spot identification, door open recovery times, as-found and as-left instrument readings, measurement uncertainty statements, and reference standard traceability documentation. Recommendations for requalification frequency are provided based on applicable standards and regulatory requirements.

Compliance & Standards

ICH Guidelines — Pharmaceutical Stability Testing

The International Council for Harmonisation (ICH) guidelines Q1A(R2) define the conditions for pharmaceutical stability testing: 25°C/60% RH (long-term), 30°C/65% RH (intermediate), and 40°C/75% RH (accelerated). Stability chambers used for ICH studies must demonstrate documented temperature uniformity of ±2°C and humidity uniformity of ±5% RH across the usable workspace. Calibration and mapping must be performed at each ICH condition to satisfy regulatory filing requirements.

IEC 60068 — Environmental Testing

International standard series specifying environmental test procedures for electronics, electrical equipment, and other products. IEC 60068-3-5 provides guidance on the confirmation of the performance of temperature chambers, including temperature mapping procedures and uniformity calculations. IEC 60068-3-6 covers combined temperature/humidity chambers.

ISTA Protocols — Package Testing

The International Safe Transit Association (ISTA) protocols specify environmental conditioning requirements for package performance testing. ISTA 7D (thermal transport simulation) and related protocols require calibrated environmental chambers with documented temperature accuracy and uniformity.

Additional Standards

  • ISO/IEC 17025 — General requirements for the competence of testing and calibration laboratories
  • MIL-STD-810 — Environmental engineering considerations for military materiel
  • ASTM E2251 — Standard test method for liquid-in-glass thermometers for environmental chambers
  • FDA 21 CFR Part 211 — Pharmaceutical current good manufacturing practice (cGMP)
  • WHO TRS 961 Annex 2 — Stability testing guidelines

Industry Applications

Pharmaceutical & Biotech

Stability chambers used for ICH long-term, intermediate, and accelerated stability studies are calibrated and mapped to documented uniformity tolerances. Photostability chambers for ICH Q1B testing and walk-in stability rooms for large-scale pharmaceutical storage studies are included. FDA and international regulatory agencies require documented chamber qualification for stability data submitted in regulatory filings (NDA, ANDA, BLA).

Electronics & Semiconductor

Thermal cycling chambers for component reliability testing, burn-in ovens for semiconductor screening, HALT/HASS chambers for accelerated life testing, and temperature/humidity chambers for moisture sensitivity level (MSL) testing are calibrated on-site. JEDEC standards require calibrated environmental chambers with documented uniformity for qualification testing.

Aerospace & Defense

Environmental test chambers used to qualify components and systems for extreme temperature exposure per MIL-STD-810 are calibrated and mapped. Thermal vacuum chambers for space hardware qualification and altitude simulation chambers for avionics testing are included. Department of Defense contracts require calibrated test equipment with documented NIST traceability.

Automotive

Climate chambers for vehicle component testing, thermal cycling chambers for electronic module qualification, and humidity chambers for corrosion testing are calibrated to documented specifications. IATF 16949 and OEM-specific requirements mandate calibrated environmental test equipment.

Environmental Chamber Calibration in Rockford

On-site environmental chamber calibration is performed at pharmaceutical, electronics, aerospace, and automotive facilities in Rockford and the surrounding Illinois area. Temperature mapping, humidity verification, and chamber qualification are conducted by ISO/IEC 17025 accredited laboratories using NIST-traceable reference sensors and data acquisition equipment. All calibration certificates are issued on-site upon completion of the measurement work.

Facilities in Rockford, IL requiring environmental chamber calibration for ICH stability testing, product reliability testing, or regulatory compliance are served through Temperature Calibration Specialists. Standard and priority scheduling is available.

ISO/IEC 17025
Accredited
IEC 60068
Compliant
NIST
Traceable
ICH
Compliant

Schedule Chamber Calibration in Rockford

ISO/IEC 17025 accredited environmental chamber calibration — including temperature mapping, humidity verification, and stability chamber qualification — is available on-site at facilities in Rockford. Contact us to schedule service or request a quote.

Request a Quote Call: (630) 488-6751